Open the Manage MxBus Modules dialog to view information on the MxBus modules that are attached to the camera.
This section allows activating/deactivating the MxBus interface. The section also lists the current status of the attached MxBus modules and allows opening the status log.
This section allows resetting all attached MxBus modules to their factory defaults. In addition, you can backup the configuration of each MxBus module or restore the configuration from a backup you created earlier.
On cameras with door station functionality, you can also start the initial operation of the door station modules (e.g., KeypadRFID and MX-DoorMaster).
This section shows information on the attached MxBus modules (serial number, software version, hardware version) and allows activating/deactivating the Classic Mode for some MxBus modules.
Some MxBus modules can be used in Classic Mode, some modules can only be used in classic mode, others only in MxMessageSystem mode ("non-classic mode").
The following table shows the differences between the classic mode and the MxMessageSystem mode:
Classic Mode |
MxMessageSystem Mode |
---|---|
|
|
The Status Details column shows the current communication status of the camera and the MxBus module:
Value |
Explanation |
---|---|
Active |
The module is properly attached to the system and communication is encrypted. |
Available |
The module is available, but communication is not yet encrypted. |
Not available |
Communication with this module has been disrupted. Click on Remove to permanently remove the corresponding module from the configuration. |
Invalid Encryption |
Communication with this module has been disrupted. Restore the configuration using the appropriate encryption data or reset the module to factory defaults. |
For modules that are marked by , you can change individual parameters of the configuration. Click on the icon or the module name to see the parameters that are available for this module:
Parameter |
Description |
||||||
---|---|---|---|---|---|---|---|
Cable Termination |
This parameter allow configuring the MxBus cable termination. Termination needs to be activated in the last module of the chain. |
||||||
Output Mode |
Sets the operating mode of the outputs of the MX-DoorMaster. You can set the following options:
NoteThis parameter is only available for the MX-DoorMaster. |
||||||
Backup Power |
This section allows checking the status of the backup power supply by the MX-DoorMaster. Note that the backup power supply allows opening the door even in case of a power failure. NoteThis parameter is only available for the MX-DoorMaster. |
||||||
RFID Encryption |
This parameter allows setting the RFID encryption type for the KeypadRFID and BellRFID modules. By factory default, this has been set to 3K3DES, which combines good reading range of RFID transponders with high security. If required, you can use AES encryption, but you should consider that this reduces the effective RFID reading range. NoteThis parameter is only available for KeypadRFID and BellRFID. |
||||||
Background Illumination |
This parameter allows setting the background illumination for the KeypadRFID and BellRFID modules. You can choose a specific level of illumination or an automatic setting, which adjusts to the ambient illumination. NoteThis parameter is only available for KeypadRFID and BellRFID. |